The Aquatherm® is a First Co. Air handler that converts a properly sized gas or oil-fired water heater into a highly efficient, dual - purpose appliance that. Kit number 941-1 can be field installed on any Aquatherm® air handler or add -on. HVAC Equipment. FMW Distributors offers exceptional pricing on all First Co. HVAC equip ment.Since it was founded in 1966 to provide the rapidly growing HVAC industry with an independent source of fan coils, First Co. Has earned an enviable reputation as a leader, innovator, and trusted supplier of a broad range of quality HVAC products. FIRST CO.® How to determine the date of production/manufacture or age of FIRST CO.® HVAC Systems. The date of production/manufacture or age of FIRST CO.® HVAC equipment can be determined from the serial number located on the data plate. Parent Company: FIRST CO. First co air handler wiring. Any york distributor should be able to accomidate u get ur model and serial number and call ur york dealer they.

Lennox: Either the first two or second two digits are the year, it varies by era, but most of them actually have a separate sticker somewhere that has the year printed on it. Newer ones are first two equals manufacturing plant #, 2nd two are year and letter in fifth slot is month (A thru M minus I). So 5898G 07568 would be Plant # 58, Year of MFR would be 98 and month would be July. Rheem & Rudd: in the middle of the serial number will be a letter 'F' the following four numbers are the week and year. The first letter of the serial number gives the year of manufacture as follows: TRANE Trane uses alpha codes in their serial numbers to determine year of manufacture. They started this in 1987 with the letter B and skipped a couple of letters during the years.

The expansive complex boasts both the most up-to-date manufacturing equipment available and a stable, experienced, highly skilled workforce. Manufacturing capabilities range from the ability to produce short runs of specialized products built to customer specifications, to the kind of high volume production capacity required in manufacturing the standard two to twenty ton units that comprise the First Co. Products line of commercial and residential air handlers. Engineering: Engineered systems produced by the company are characterized by a commitment to quality and performance that sets a standard of excellence few companies can match.

After April 1992, 1st two numbers are year, then month, then series. Call 905-672-0860 if you get stuck. Comfortmaker (International Comfort)Uses the first letter for the month (skipping I) and the first two digits are the year.

Hot water from a gas fired water heater is piped through the air handler coils to heat the house via forced air. To me, it seems like a good, simple system, but I don't know much about them. The house is also well insulated and when it was built(2007), I remember the builder advertising that if the electric and gas combined exceeded $60 per month(for the first year), they would pay you the difference. Pretty good guarantee for a 1200 square foot house! Anyway, anyone know about these systems and if so, what do you think of them? Thanks very much for any help.

If you sell your home the registered limited warranty will change to base limited warranty on the date of home sale. The new home owner will have any remaining base limited warranty. For registered limited warranties completed on or after August 1, 2011 to maintain the remaining balance of the existing limited warranty the limited warranty must be transferred within 90 days of home sale. Either you or the new home owner must notify Trane of the warranty transfer within 90 days of the home sale for the transfer to be effective. Transferability restrictions may vary by state.

Your use of any such or similar incorporeal property is at your own risk. This guide is intended to assist Commercial/Residential Building Inspectors, HVAC professionals, Facilities Managers, HOA’s, etc., in determining the date of manufacture and/or age of HVAC equipment to determine the expected useful life (EUL). This web site should not be relied upon for commercial use or interpretations. Accuracy and reliability of the information provided is believed accurate but is not guaranteed. The burden for fitness of information provided relies solely and completely with the user. In no event will Building Intelligence Center or its representatives be liable for any loss or damages whatsoever for consequential, incidental, indirect, special, or tort damages of any kind, including but not limited to loss of data, lost profits, business interruption, loss of business information, or other pecuniary loss that might arise from the use of or reliance on the information provided within.

Has earned an enviable reputation as a leader, innovator, and trusted supplier of a broad range of quality HVAC products. FMW Distributors only sells to other businesses, government agencies and general contractors. Unfortunately, we do not sell to the general public and cannot drop ship orders to residential addresses, except for orders placed by general contractors. If shipment is made to a general contractor's residential address, a resale certificate must be faxed prior to placing an order. Commercial Products.

Look behind the door of the air handler to see the wiring diagram. They should have the color coded speeds marked on the diagram. There is probably some sort of control board that the blower speed taps plug into. By changing these wires around on these taps you can adjust the speed of the blower motor. Jun 05, 2010 .

Your post brought up an important question I hadn't thought of: Is a hydronic heating system like the Aquatherm 'Combo Heater' enough to heat a house(albeit well insulated) or does it need a heat pump to help it? Thanks again very much for any help. Whether or not the system can heat the house depends on the total amount of heat that can be produced and distributed by the system as per the water heating capacity, the hydronic coil capacity and the amount of air volume the blower/distribution system can handle versus the heat loss of the house. I personally would always opt for a hydronic coil in the supply airstream of a heat pump system for more versatility in fuel usage as well as having two means of heating my home. The First Co. Hydronic air handlers are good units; I have seen them used in a number of commercial applications. Have seen them in only one house and they didn't need any auxiliary heat.

The photos and diagrams will help you locate the model and serial numbers of your equipment, if they are not found on your original warranty or sales invoice. Split Systems Two Model and Serial Tags identify Split System Equipment Package Systems One Model and Serial Tag Identifies Package Equipment.

Here is a basic wiring diagram for all air cond systems your thermostat consist of treminal r w y and c run a four conductor wire fromm thermostat to ai handler the air handler should allso have eather have red blue white wires or a teminal block marked r w c r stands for red w for white c for comon allso blue run color for color from the thermostat to ai handler with exeption of yellow yellow runs straigth to condenserand retuns in white wire to air handler wich gets conected to comon hope this help[s you Sep 02, 2007 .

Please affirm that your unit was installed by a dealer. Note that we will ask for the installing dealer's name and contact information during the rest of the registration process. Congratulations!487 You are eligible for an additional limited warranty on the. Ancient aliens season 1 free torrent download. Specifically, you will receive a new unit if your compressor or heat exchanger fails during the next 0 years and you own your home. To receive this added benefit, you will need to have a state licensed HVAC contractor of your choice provide maintenance on an annual basis, as well as meet other stated terms in your warranty. On the following page, we will ask you to confirm your intent to have annual maintenance in order to receive this no cost additional limited coverage.

PHONE: 936-582-4616 ♦ FAX: 936-448-4699 First Co. HVAC Equipment FMW Distributors offers exceptional pricing on all First Co. HVAC equip ment. Since it was founded in 1966 to provide the rapidly growing HVAC industry with an independent source of fan coils, First Co.

(The letter D in the Sample represents 1964). 1962 = B 1963 = C 1964 = D 1965 = E 1966 = F 1967 = G 1968 = H Letter “I” was not used. 1969 = J 1970 = K 1971 = L 1972 = M 1973 = N 1974 = O 1975 = P Letter “Q” was not used. 1976 = R 1977 = S 1978 = T 1979 = U 1980 = V Bard April & May 1980 Sample number 123 D A 123456 1st three digits are the Compressor Part Number. 4th digit is the month of Manufacture. In this sample D represents April. D = April F = May 5th digit is the year of Manufacture.

Any of the trademarks, service marks, collective marks, design rights or similar rights that are mentioned, used or cited in the articles of the Building Intelligence Center (www.buildingcenter.org) are the property of their respective owners. Their use here does not imply that you may use them for any purpose other than for the same or a similar informational use as contemplated by the original authors of these articles under the CC-BY-SA and GFDL licensing schemes. Unless otherwise stated Building Intelligence Center (www.buildingcenter.org) sites are neither endorsed by nor affiliated with any of the holders of any such rights and as such Building Intelligence Center (www.buildingcenter.org) cannot grant any rights to use any otherwise protected materials.

I'm bringing this over here for future reference. HVAC AGE CODES IN SERIAL # INFO Amana: BLACKHORSE. B=1971 or 1981. (Of course, now that they've been bought by Goodman, who knows what'll happen.) BARD 1962 to March 1980 Sample Number 123456 A D 1st six digits are the Unit Identity Number. In this example they are represented by the numbers 123456.

Previously, it was a complex series of letters and single digits. Call 905 672-0860 if you get stuck. Coleman: Serial numbers prior to April 1992=1st two numbers are month, then year, then series. After April 1992, 1st two numbers are year, then month, then series. Comfortmaker (International Comfort) uses the first letter for the month (skipping I) and the first two digits are the year. First Company Service Parts is one of 4 divisions of First Operations. They supply OEM equipment to all of the major HVAC manufacturers.

AIR-CONDITIONER DATE CODES (serial #) AMANA / BLACKHORSEB=1971 or 1981 (Of course, now that they've been bought by Goodman, who knows what'll happen) BARD1962 to March 1980 Sample Number 123456 A D 1st six digits are the Unit Identity Number. In this example they are represented by the numbers 123456. 7th digit is the month of Manufacture. 8th digit is the year of Manufacture.

(The letter D in the Sample represents 1964). 1962 = B 1965 = E 1968 = H 1970 = K 1973 = N Letter 'Q' not used 1978 = T 1963 = C 1966 = F Letter 'I' not used 1971 = L 1974 = O 1976 = R 1979 = U 1964 = D 1967 = G 1969 = J 1972 = M 1975 = P 1977 = S 1980 = V April & May 1980 Sample number 123 D A 123456 1st three digits are the Compressor Part Number. 4th digit is the month of Manufacture. 5th digit is the year of Manufacture. In this sample A represents 1980.

Call 905-672-0860 if you get stuck. ColemanSerial numbers prior to April 1992=1st two numbers are month, then year, then series.

Example – 1205, this would have been build in May of 2001. Anything without the addition to the serial number would have been made before 1984 and would require contact with the factory.

That house did have a problem, though. Domestic hot water had priority, which meant that when domestic hot water was being produced there was no hot water available for space heating. The owners were able to put up with that for several years until their kids became teenagers and domestic hot water useage increased. I added a switch so they could choose whether domestic hot water or space heating had priority, but it was still a compromise. But apparently not too much of a compromise for them, because the system is still in operation. Quick Navigation • Site Areas • • • • • • • Forums • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •.

In this sample A represents 1980. 1980 = A This serial number style was only used during the months of April & May 1980. 6th thru 11th digits represent the Unit Identity Number. Bard June 1980 to Current Sample number 123 H 02 1st three digits = Compressor Part # 4th digit = Month A = January B = February C = March D = April “E” was not used F = May “G” was not used H = June “I” was not used J = July K = August L = September M = October N = November “O” was not used P = December 5th & 6th digits = Year 80 = 1980 81 = 1981 82 = 1982 right on thru. The year 2000 started the numerical numbering from 00. 00 = 2000 01 = 2001 02 = 2002 right on thru to current date. 7th thru 13th digits = Unit Identity # 14th & 15th digits = Factory Code (01=OH; 02=GA) Carrier, Bryant, Payne, Day & Night: Recently (last 20 years or so) the first four numbers in the serial number represent the week and year.

They are located in Dallas, Tx at 214-388-5751. Harold Hammer at Tech Support (ext#5) will answer your questions. Goodman: First two digits of the serial number are the year. Second two are the month. Btu rating is model number.ie; GMP075-3 (75,000 bonnet input) Compressor is same:serial # (yr1997 wk 09) Tonnage is model # CK361C The first two numbers after the CK (letters) divided by 12 is tons. Ie: 36 div by 12= 3 tons.

There are many variations of hydronic heating coils in air systems on the market. I've always had success with them on retrofit systems where the coil was seperate from the air handler. First Company is a good manufacturer with much experience with hydronic heating coils in DX coil cooling air handlers. More of a concern is the condition of the outdoor unit. If it is old and cooling only, consider having it replaced with a heat pump.Your post brought up an important question I hadn't thought of: Is a hydronic heating system like the Aquatherm 'Combo Heater' enough to heat a house(albeit well insulated) or does it need a heat pump to help it? Thanks again very much for any help.

It will have a bar code on it. Call (or email) Wiel McLain and they will tell you the date of manufacture. Phone: 219-879-6561 ask for Technical Services Peerless Prior to 1984 there was not a date code included as part of the serial number. Starting in 1984, there was a four digit date code following the serial number that was month and year. Example – JO-, this unit was built in October of 1984. Starting in the year 2000, same idea only it was a six digit date code following the serial number that is year and month.

Should you have a problem with your system, Ruud has developed the following guidelines to assure that your problem receives proper attention. To better assist your independent HVAC contractor, please furnish the model and serial numbers on each piece of your equipment and the date of installation. First, determine the type of equipment from the two categories shown below.

Since it was founded in 1966 to provide the rapidly growing HVAC industry with an independent source of fan coils, First Operations has earned an enviable reputation as a leader, innovator, and trusted supplier of a broad range of quality HVAC products. Manufacturing: The company's production facilities are located in Dallas, Texas where they have steadily grown to their present size of more than 600,00 square feet.

• Air Conditioners - compressor, outdoor coil, internal functional parts • Heat Pumps - compressor, outdoor coil, internal functional parts • Furnaces - heat exchanger, internal functional parts • Coils - internal functional parts • All-in-One Systems - heat exchanger (where applicable), compressor, coil, internal functional parts • Handlers - internal functional parts • Air Cleaners - internal functional parts (excludes filters) • Humidifiers - internal functional parts • Controls and Thermostats - internal functional parts. Both the Base and Registered Limited Warranty for your Trane product are only valid to for the original purchaser. If you are selling your home changes to the Limited Warranty may apply, please read below. Registered limited warranties completed prior to August 1, 2011 are not transferable to subsequent homeowners.